KT88-3232 Channel EEG Machine with Software
Introduction
KT88-3200 Digital Brain Electric Activity Mapping collects EEG signal with electrodes, via integrated amplification, A/D transformation, PC auto-analysis, FFT, to form electroencephalogram that displays with color depth. The product is applicable for checking such diseases as epilepsy, intracranial inflammation, cerebrovascular diseases and brain tumors.
Features
Method of 10/20 electrodes placement under international standard system, leads can be changed during replaying. Support different types of combined leads during sampling.
Adopt bioelectricity amplifier for distilling brainwave, continuous recording time can be up to 24 hours, integrated full-automatic calibration system.
Powerful playback function: amplitude and display speed are adjustable. The special subdividing time line divides the waveform in one second into 5 parts, which is easy for doctors to look over the waveform.
Digital filter system can be set as required, providing different window types
EEG signal clipping function, analyze and store any section of EEG wave, and select several waveform segments for automatically analyzing and distilling to different parameters.
Electronic frequency ruler, convenient to measure the basic information of any appointed EEG waveform. With partial enlarging window, accurate measurement of EEG period, amplitude and frequency, which can be adjusted according to personnel judgment.
Mark EEG wave under the events of opening eyes, closing eyes and flashing with different colors, and user-defined events can be added, waveform color for evoked event can also be set freely, ensures that the waveform in corresponding time can be rapidly found by event name during case playback.
Powerful automatic analysis function, can carry through the power spectrum analysis and pathologic wave detection for appointed waveform. Many graphs can be displayed in the same screen, including kinds of BEAM, numerical BEAM, compressed spectrum graph, trend graph, and so on.
Professional isolation transformer, dual power supply isolation system and optoelectronic data transmission to ensure security. Use USB interface to transmit data which just need to be inserted.
Multifunctional flash stimulator of USB interface, and flashing can be controlled manually or automatically. A flash stimulation scheme can be set and performed in the process of sampling.
Perfect case management function, provides many means for research and quick statistic information; convenient case export and import function, and stores with MO or CD-RW disk, which is easy for data research.
Integrative image and character report, report can be edited in mode and switched to Word document.
Case files can be transformed into EDF and BDF data format, convenient for data exchange, academic exchange and further analysis.
System parameters and display modes can be set as required, which meets different user’s requirement.
Add marks and annotations to the waveform designated, which can rapidly find the waveform in that time by marks.
Optional video function: USB camera is easy to install, convenient to use and exact to record. With flexible playback function, which can browse the waveform of any time along with the corresponding isochronous sampled image.
SpO2 function is optional.
Performance
32 channels of EEG
Sampling rate: 200 dots/s
Accuracy: 12bit
Input impedance: ≥10MΩ
Patient leak current: < 10µA
Noise level: ≤5µVp-p
CMRR: ≥90dB
Magnification multiple: 10000
Filter constant: all digital and free enactment
Display speed(paper speed): 5, 10, 15, 30, 60, 120 mm/s
Amplitude: 1, 1.5, 2, 3, 5, 7.5, 10, 12, 15, 20, 30, 50 mm/50µV
Playback speed:1 time, 2 times, 3 times, 10 times, 20 times, 40 times, 60 times
50Hz interference suppression: ≥30dB
Safety type:Class II, type BF applied part
Accessories
Standard
EEG lead
EEG electrode
Data line
Headgear
Strobe light
Strobe light power supply
PC software CD
User Manual
Earth wire
EEG bracket
Aluminum block
Optional
SpO2 module, video module
Physical characteristic
Dimension: 186 mm(L)×186 mm(W)×89.2 mm(H)
Weight: 750g
Operational environment:
Temperature: +5℃~+40℃
Relative humidity: ≤85%
Atmospheric pressure: 700hPa~1060hPa
Power supply: USB 5V DC
Storage environment:
Temperature:-20℃~+55℃
Relative humidity: ≤90%
Atmospheric pressure: 700hPa~1060hPa
Buy safe Product
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved
Please use under the doctor's instruction
Shipping:
1). We will ship within 1 business day after your payement ;ship from China warehouse by China Post 2-4 weeks Arrival
2).We don't add taxes, VAT or other hidden charges. You pay us what you see on the invoice, i.e. goods subtotal + shipping cost (not include duties). Please find out as much as you can about your import taxes in your own country before bidding the item. You need to pay for the import duties in case that occurred for certain goods, or you may kindly give us some suggestions about that, we promise to do our best to help you!
About Warranty:
We guarantee new equipment other than accessories to be free from defects in workmanship and materials for a period of twelve months (six months for spare parts) from the date of shipment under normal use and service. Our company's obligation under this warranty is limited to repairing, at our company's option, any part which upon our company's examination proves defective.
Return Policy:
If you receive a defective item which you want to return, please contact us within 5 days from the day you receive the item. All return items must be returned with its original packaging and accessories. If we confirm the damage happened during the shipment, we will bear the shipping cost for return.
We will refund the money to you when we get the return items. Or replace item for you free of charge.